Wiring Diagrams

Please find on this page all of our wiring diagrams for exit devices with electric latch retraction. You can view/download any wiring diagrams by clicking the .pdf icons below.

If you need any further assistance with sales or marketing materials please contact: sales@fcbp.com

The following wiring diagrams are for our Motorized Electronic Latch Retraction (MEL) devices. Our motor devices require and in-rush current of 24 Vdc and 1 A (must be filtered and regulated).
Single Door

MEL Exit Device/s: 1 Single Door w/ 1 Active

Power Supply: PSMEL1500

MEL Exit Device/s: 1 Single Door w/ 1 Active

Power Supply: PSEL1500

MEL Exit Device/s: 1 Single Door w/ 1 Active

Power Supply: PSMEL2000

ADA Compliant Door

MEL Exit Device/s: 1 Single Door w/ 1 Active

Power Supply: PSMEL2000

With Accessories: Door Position Switch

MEL Exit Device/s: 1 Single Door w/ 1 Active

Power Supply: PSMEL2000

With Accessories: Reception Desk Switch

MEL Exit Device/s: 1 Single Door w/ 1 Active

Power Supply: PSMEL2000

With Accessories: Reception Desk Switch, Over-ride Key

Pair of Doors

MEL Exit Device/s: 1 Pair of Doors w/ 1 Active

Power Supply: PSMEL1500

MEL Exit Device/s: 1 Pair of Doors w/ Both Active

Power Supply: PSMEL2000

MEL Exit Device/s: 1 Pair of Doors w/ Both Active

Power Supply: PSMEL2000

ADA Compliant

MEL Exit Device/s: 1 Pair of Doors w/ Both Active

Power Supply: PSMEL2000

With Accessories: Reception Desk Switch

2 Separate Doors

MEL Exit Device/s: 2 Separate Doors w/ Both Active

Power Supply: PSMEL2000

MEL Exit Device/s: 2 Separate Doors w/ Both Active

Power Supply: PSMEL2000

ADA Compliant

The following wiring diagrams are for our Electronic Latch Retraction (EL) devices. Our EL devices are driven by a solenoid which requires and in-rush current of 24 Vdc and 16 A (must be filtered and regulated). Our EL devices must be powered with either the PSEL1500 (single device) or PSEL3000-2 (two devices) for warranty purposes.
Single Door

EL Exit Device/s: 1 Door w/ 1 Active

Power Supply: PSEL1500

EL Exit Device/s: 1 Door w/ 1 Active

Power Supply: PSEL3000-2

EL Exit Device/s: 1 Pair of Doors w/ 1 Active

Power Supply: PSEL1500

Pair of Doors

EL Exit Device/s: 1 Pair of Doors w/ 1 Active

Power Supply: PSEL1500

EL Exit Device/s: 1 Pair of Doors w/ 1 Active

Power Supply: PSEL3000-2

EL Exit Device/s: 1 Pair of Doors w/ Both Active

Power Supply: PSEL3000-2

EL Exit Device/s: 2 Pairs of Door w/ 1 Active on Each Pair

Power Supply: PSEL3000-2

2 Separate Doors

EL Exit Device/s: 2 Separate Doors w/ Each Active

Power Supply: PSEL3000-2

Wire Distance Chart

PSEL3000-2 Wire Distance Chart